Safety Technology International, Inc.
2
306 Airport Road • Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Fax: 248-673-1246
Toll Free: 800-888-4784 E-mail: info@sti-usa.com
Web: www.sti-usa.com
Safety Technology International (Europe) Ltd.
U
nit 49G Pipers Road • Park Farm Industrial Estate • Redditch
W
orcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 Freephone: 0800 085 1678 (UK only)
E-mail: [email protected] • Web: www.sti-europe.com
IMPORTANT:
Do not attempt to install detector guards until both the transmitter and receiver
have been perfectly aligned and tested. Lag shields are for use in concrete and
the mortar joints of block or brick walls. For wood installations drill pilot holes
13/64” diameter for lag screws only. Lag shields are not required for this type
of installation. Do not install guard on hollow backed drywall.
SERVICE
When servicing, remove the center lag screw on top of the guard then loosen
the other (5). The guard may now be slid upward and removed. Use caution
not to hit or bump the detectors or misalignment may occur.
INSTALLATION INSTRUCTIONS
1. After alignment center the wire guard over existing System Sensor smoke
beam. Slots must have openings facing downward as shown.
2. Use the guard as template with the center mounting hole and (2) slots on
top (as shown). Position guard to allow projected beam to pass through
one of the 1 1/2 in. grid openings.
3. Mark and drill (6) 1/2 in. diameter holes 1 1/2 in. deep.
NOTE: If after installation, interference of the projected beam is passing to
close to one of the wire struts, the interfering strut may be cut and
removed without structural weakening or loss of warranty.
INSTALLATION OF STI BEAM SMOKE DAMAGE STOPPER STI-9625
All specifications and information shown were current as of publication and are subject to change without notice.
9625 MARCH2013
SIDE VIEW
7
.875 in.
(200mm)
TOP VIEW
1
2.625 in.
(321mm)
10.25 in.
(
260mm)
S
19006 LAG SHIELDS
1/4 in. x 1 1/2 in.
(
6) PROVIDED
19005 LAG SCREW
1/4 in. x 1 3/4 in.
(6) PROVIDED
EXISTING 6424 SYSTEM
SENSOR SMOKE BEAM
APPROVALS
UL/cUL Listed (No. S3504) for use with System Sensor beam detector model 6242.
Electronic warranty form at www.sti-usa.com/wc14
Seitenansicht 0
1 2

Inhaltsverzeichnis

Seite 1

Safety Technology International, Inc.2306 Airport Road • Waterford, Michigan 48327-1209Phone: 248-673-9898 • Fax: 248-673-1246Toll Free: 800-888-4784

Seite 2

SMOKE DETECTOR COVERSSTI-9601 Low profile - Flush mountSTI-9601-SS Low profile - Flush mount -Stainless Steel

Kommentare zu diesen Handbüchern

Keine Kommentare